North American Network Operators Group Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical Re: MAE-East snafu redux
Well, from our router (1292.41.177.103, catalyst 6) it looks like this (note the packet loss!!!) Jan There the pings: core0.mae-east#ping 192.41.177.181 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 192.41.177.181, timeout is 2 seconds: .!.!! Success rate is 60 percent (3/5), round-trip min/avg/max = 100/189/268 ms core0.mae-east#ping 192.41.177.181 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 192.41.177.181, timeout is 2 seconds: !!!.! Success rate is 80 percent (4/5), round-trip min/avg/max = 4/13/20 ms core0.mae-east#ping 192.41.177.113 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 192.41.177.113, timeout is 2 seconds: !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 8/11/16 ms core0.mae-east#ping 192.41.177.101 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 192.41.177.101, timeout is 2 seconds: .!.!! Success rate is 60 percent (3/5), round-trip min/avg/max = 4/8/12 ms core0.mae-east#ping 192.41.177.101 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 192.41.177.101, timeout is 2 seconds: .!!!. Success rate is 60 percent (3/5), round-trip min/avg/max = 1/28/44 ms core0.mae-east#ping 192.41.177.73 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 192.41.177.73, timeout is 2 seconds: !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 12/17/24 ms core0.mae-east#ping 192.41.177.119 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 192.41.177.119, timeout is 2 seconds: !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 16/19/24 ms core0.mae-east#ping 192.41.177.69 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 192.41.177.69, timeout is 2 seconds: !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 1/3/4 ms --- Jeremiah Kristal wrote: > Has everyone just become so used to terrible performace at MAE-East, or am > I the only one seeing problems? I'm seeing perfect performance to > networks connected to Gigaswitch 1 (excluding overloaded ports), but > 15-20% packet loss to anyone connected to any other Gigaswitch. In the > past MFS would jump on these tickets, find a frozen card on Gigaswitch 6, > reset it, and clear the trouble. It has been over 24 hours since I opened > a ticket, I've spoken with MFS Datanet Engineering, and I still don't > think I've spoken to anyone at MFS who is aware that all traffic between > Gigaswitches goes through Giga6. > If anyone has time tonight, could they check performance to other > providers on the same Gigaswitch and on other Gigas. If you need to know > which provider is on which switch, go to > http://www.mfsdatanet.com:80/MAE/east.map.html > Thanks, and hopefully this is on topic, even if it doesn't contain actual > router commands. :) > > Jeremiah Kristal > Senior Network Engineer > ICon CMT Corporation > jeremiah@iconnet.net > 201-319-5764 > x284 internal
|