Interaction of IGP and BGP
Use loop-back addresses for IBGP, and advertise loop-back as next-hop
IGP for topology and next-hop
IBGP Hold timer larger than 2* IGP timer
Avoid overly meshed topology
- Engineer flooding topology to prune excessive IGP flooding for dense topology
Adjustment of various IGP timers to favor stability over convergence